The EVEREST290 PAE WA Kp is a modular air/water heat pump with 2 pipes that is suitable for heating and cooling. Compared to the classic air/water heat pump PAE 881 Kp, this "WA" version has a plate exchanger and an air-side battery that have been optimized for cooling. The cooling capacity of this unit is no less than 59% higher than the standard PAE 881 Kp. Up to 10 of these modules can be placed in a cascade system. The monoblock unit is filled with the natural refrigerant propane (R290) and can reach outgoing water temperatures of up to 65°C.
The EVEREST290 is an appliance for heating and cooling that uses 2 scroll compressors with the same capacity. This ensures 2 power stages and low power consumption. Due to the specific construction, the appliance will switch to defrost mode less quickly and the defrost cycle is completed as efficiently as possible.
The unit maintains its high COP values ​​even at negative outside temperatures.

Brand

  • Emicon

Application

  • Production of domestic hot water (up to 65°C)
  • Heating or cooling in commercial applications
  • Heating or cooling in industrial applications

Characteristics

Per module:
  • PAE 881 WA Kp: Cooling capacity: 105 kW / Heating capacity: 88,2 kW
  • In heating mode:
Outgoing water temperature up to 65°C at 0°C outdoor temperature
Outgoing water temperature up to 50°C at -20°C outdoor temperature
  • In cooling mode with glycol:
Outgoing water temperature down to 0°C at -20°C outdoor temperature

Composition

  • Modules of monoblock 2-pipe heat pumps that can be used stand-alone or in a cascade of maximum 10 units
  • Reliable operation
  • Maintenance-free propane leak detector
  • Strong, compact, steel structure with powder coating RAL 7035
  • Movable with hand pallet truck
  • 2 EC fans
  • 2 scroll compressors in tandem with crankcase heating in a soundproof casing
  • Electronic expansion valve
  • Insulated stainless steel plate exchanger with flow switch
  • Copper/aluminium batteries mounted in V with innovative mini-channel technology and hydrophilic coating
  • Winter regulation down to -20°C
  • Phase monitor
  • Plug-and-play hydraulic and electrical connections

Options

  • Rubber anti-vibration mounts. Type PA-Kp (PAE GPE)
  • Anti-vibration mounts with springs. Type PM-Kp (PAE GPE)
  • Soundproofing jacket on compressors. Type Cl-Kp (PAE GPE)
  • Ampere and voltmeter used to measure the electrical current absorbed and the electrical supply voltage of the unit. Type A+V-Kp (PAE GPE)
  • Tablet interface kit in combination with KGR5/10 or KGH/10 kit in modular use. Type KTA-Kp (PAE GPE)
  • Remote display. Type PQ-Kp (PAE GPE)
  • Water collector kit without insulation (1 per unit). Type KCA-Kp (PAE)
  • Insulation for water collector. Type KCC-Kp (PAE)
  • Gateway framework kit for 2 to 5 units in modular use (1 in case of multiple units). Type KG5-Kp (PAE GPE)
  • Gateway framework kit for 6 to 10 units in modular use (1 in case of multiple units). Type KG10-Kp (PAE GPE)
  • Gateway kit for stand-alone unit with Hi-web and Wi-Fi router. Type KGH1-Kp (PAE GPE)
  • Gateway board kit for 2 to 5 units in modular use with Hi-web and Wi-Fi router (1 case of multiple units). Type KGH5-Kp (PAE GPE)
  • Gateway board kit for 6 to 10 units in modular use with Hi-web and Wi-Fi router (1 in case of multiple units). Type KGH10-Kp (PAE GPE)
  • Gateway kit for stand-alone unit with Wi-Fi router. Type KGR1-Kp (PAE GPE)
  • Gateway board kit for 2 to 5 units in modular use with Wi-Fi router (1 in case of multiple units). Type KGR5-Kp (PAE GPE)
  • Gateway board kit for 6 to 10 units in modular use with Wi-Fi router (1 in case of multiple units). Type KGR10-Kp (PAE GPE)
  • Display interface kit for monitoring leak detector. Type KLD-Kp (PAE GPE)
  • Electrical switch and connection board for a kit up to 5 modules (connect main power here in case of cascade). Type KP5-Kp (PAE GPE)
  • Electrical switch and connection board for a kit up to 10 modules (connect main power here in case of cascade). Type KP10-Kp (PAE GPE)
  • Victaulic cap + socket kit/welded. Type KTT-Kp (PAE GPE)
  • Lifting brackets securely attached to the frame to lift the unit with hooks and cables. Type MG-Kp (PAE GPE)
  • Manometers in front panel. Type MT-Kp (PAE GPE)
  • Anti-freeze tracing around the evaporator. Type RA-Kp (PAE)
  • Double insulation around the evaporator. Type VB-Kp (PAE)
  • Anti-freeze tracing around the internal hydraulic pipes. Type VH-Kp (PAE)

Versions

  • PAE 881 WA Kp
  • PAE 881 Kp

Order example

  • PAE 881 WA Kp
Explanation
88

=

Nominal heating capacity (kW)

1 = Number of cooling circuits

WA = Plate exchanger optimised for cooling

Kp = Propane refrigerant

Specifications

EVEREST PAE 881 WA Kp
Nominal cooling capacity (EN14511) (1)kW105
Total input power in cooling (EN14511)kW29,6
Total nominal current per module in coolingA55
EER (EN14511) 3,55*
Number of refrigerant circuits 1
Number of compressors 2
Number of axial fans 2
Total air flow rate of axial fans (1)m³/h38.770
Total fan input power (1)kW2,3
Total fan input current (1)A4,1
Number of plate exchangers 1
Total water flow rate of plate exchanger (1)m³/h18
Pressure dropkPa55,5*
Diameter of hydraulic connectionsDN2" Victaulic*
Total pump input power P1 (1)kW0,9
Pump input current P1 (1)A1,6
Total pump electrical input power P1 (1)kW0,5
Nominal heating capacity (EN14511) (2)kW88,2
Total input power in heating (EN14511)kW22,5
Total nominal current in heatingA46,3
SCOP (3) 3,77*
COP (EN14511) 3,92*
Total air flow rate of axial fans (2)m³/h32.470
Total fan input power (2)kW1,54
Total fan input current (2)A3,01
Total water flow rate of plate exchanger (2)m³/h15,3
Pressure dropkPa43,5*
Diameter of hydraulic connectionsDN2" Victaulic*
Total electrical pump input power P1 (2)kW0,8
Pump input current P1 (1)A1,6
Total electrical power input (unit side)kW0,3
Refrigerant charge R290kg6,1
Global warming potential (GWP) 3
Equivalent CO2 chargekg18,3
Transport weightkg835
Operating Weightkg840
Lengthmm2.560*
Depthmm1.100*
Heightmm2.450*
Sound power level (4)dB(A)87**
Sound pressure level (5)dB(A)55**
Power supplyV/Ph/Hz400/3/50+PE
The specified values ​​apply to the following conditions:
(1) Fluid: water - In/Out temperature: 7/12°C - outside air 35°C.
(2) Fluid: water - In/Out temperature: 30/35°C - outside air 7°C RH 87%.
(3) Calculated according to EU.813/2013.
(4) Sound power level in accordance with ISO 3744.
(5) Sound pressure level at 10 m from the unit in free field conditions in accordance with ISO 3744.
Technical data relating to the unit. In case of a modular system with n units, multiply the data (exept those marked with "*" ) by n to obtain the total values.
** In case of modular system see paragraph with sound data.

Specifications

Sound data EVEREST 290
Octave bands63 Hz125 HZ250 HZ500 HZ1000 HZ2000 HZ4000 HZ8000 HZLwLp1Lp10
PAE 881 WA Kp43 dB(A)51 dB(A)69 dB(A)76 dB(A)79 dB(A)84 dB(A)76 dB(A)63 dB(A)86,5 dB(A)68,3 dB(A)54,6 dB(A)
In the case of a modular system consisting of 1 to n modules, the total value of the sound level can be estimated by the following formula:
Leq tot= 10 x log 10 [n x ( 10 LW1/10)]