PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

SDA • Swimming pool dehumidifiers

Vertical ductable dehumidifier for indoor swimming pools. The SDA increases comfort and prevents mould growth and moisture damage to furniture or the building structure. The units have an epoxy coating to resist chlorine vapours. Optionally, this dehumidifier can be equipped with a heating coil for a more pleasant indoor climate. The dehumidifier does not have a built-in humidity probe. Choose from the accessories listed below for a built-in humidity probe RGDD or a remote humidistat HYGR for installation in the swimming pool area.

Brand

  • Emicon

Application

  • Dehumidification of indoor swimming pools
  • On request also available as an industrial dehumidifier (HDA version) operating up to 5°C instead of up to 20°C.

Capacity

  • 75 to 200 l/24h
  • 800 to 1800 m³/h

Accessoires

  • CANA – Flange for connection of an exhaust duct. Preformed rectangular flange for easy connection of an exhaust duct mounted on the exhaust side of the fan. (standard)
  • HYGR – Remote mechanical hygrostat for wall mounting. It comes with a control knob and a working range from 30% to 100% with an accuracy of 3%.(Not compatible with the RGDD option)
  • HOEL -Electric post-heating battery (Also take the RGDD.05 in this case).
  • HOWA -Hot water battery (on central heating water from the boiler or heat pump) to heat the air in the room after drying (also take the KIVM and RGDD.05 in this case)(not available for HDA version).
  • INSE - RS485 serial interface card. This interface card allows the controller to communicate with other devices using the Modbus protocol.
  • KIVM - 3 way modulating valve kit. It is used to control the flow of water in the battery. The 3-way valve is controlled directly from the microprocessor in this unit(not available for HDA version).
  • LS00 - Low noise version (standard).
  • PCRL - Remote control. This panel can be mounted up to 50 m (maximum) from the device and displays all control functions. It is connected using a double cable with a section of 0.75 mm².
  • RGDD - Humidity and temperature sensor. Built-in electronic temperature and humidity sensor.(Not compatible with the HYGR option)
  • RP01 - Partial heat recovery. The exchanger is designed to recover approximately 20% of the thermal capacity generated by the unit into the pool water. (water condenser)(not available for HDA version)
  • V1CE - EC-fan 300 Pa

Order example

The "SDA 200 1PH LPHW" is a stock product central warehouse unless sold and has the following options fitted as standard:


  • RGDD Humidity and temperature sensor Built-in
  • HOWA Hot water battery
  • KIVM 3 way modulating valve kit (Build-in)

Articles

Article selection assistant
Diameter D [mm]
Article number Type [mm] Diameter D [mm] E-shop
C010324080000 BDSG 30 80 80
C010324100000 BDSG 30 100 100
C010324125000 BDSG 30 125 125
C010324150000 BDSG 30 150 150
C010324160000 BDSG 30 160 160
C010324180000 BDSG 30 180 180
C010324200000 BDSG 30 200 200
C010324250000 BDSG 30 250 250
C010324315000 BDSG 30 315 315
C010324355000 BDSG 30 355 355
C010324400000 BDSG 30 400 400
C010324450000 BDSG 30 450 450
C010324500000 BDSG 30 500 500
C010324560000 BDSG 30 560 560
C010324630000 BDSG 30 630 630
C010324710000 BDSG 30 710 710
C010324800000 BDSG 30 800 800
=> Stock product central warehouse, except sales
=> Stock product local warehouses, except sales

Technical data

SDA75100150153200203
Moisture removal at 30°C - 80%l/24h7395.2157.1157.1194.3194.3
Moisture removal at 30°C - 60%l/24h56.676.5111111145.3145.3
Moisture removal at 27°C - 60%l/24h49.468.599.799.7127.8127.8
Moisture removal at 20°C - 60%l/24h34.550.266.666.690.690.6
Nominal input power(1)kW1.41.832.222.222.842.84
Maximum input power(1)kW1.822.73.03.23.5
Electrical post-heater (option)kW3364.564.5
Maximum input current(1)A7.18.112.68.115.59.5
Peak currentA253847316646
Hot water coil(2)kW7.58.513.913.915.215.2
Partial heat recovery(3)kW1.11.72.32.33.03
Air flow ratem3/h80010001500150018001800
Available static pressurePa50÷150
Refrigerant (GWP) R410A (2088)
Refrigerant chargeg (CO2eq-T)550 (1.148)1100 (2.297)
Sound power(4)dB(A)596167676969
Sound pressure level(5)dB(A)525460606262
Power supplyV/Ph/Hz230/1/50400/3+N/50230/1/50400/3+N/50

Performances are calculated with low fan speed and are referred to the following conditions:

  • (1) Without electrical heater
  • (2) Room temperature 30°C, water temperature 80/70°C, compressor OFF
  • (3) Room temperature 30°C/80%, water temperature 27/32°C, compressor OFF
  • (4) Sound Power level according to ISO 9614 fan with available static pressure 50 Pa
  • (5) Sound Pressure level measured at 1 meter from the unit in free field conditions according with ISO 9614, fan with available static pressure 50 Pa

Dimensions

 FrameA [mm]B [mm]C [mm][kg]
SDA 75F180080040085
SDA 100F180080040090
SDA 150/153F210001060550130
SDA 200/203F210001060550135

Accessories

SDA75100150153200203
Hot water coil (LPHW)HOWA.75HOWA.76
Electrical post-heating battery 3 kW (230/1/50)HOEL.30----
Electrical post-heating battery 4,5 kW (230/1/50)---HOEL.45-HOEL.45
Electrical post-heating battery 6 kW (230/1/50)--HOEL.62-HOEL.62-
Built-in electronic temperature/humidity sensorRGDD.05
Mechanical humidistatHYGR.20
Remote control panelPCRL.10
Serial card RS485-MODBUSINSE.10
Built-in 3-way valveKIVM.75KIVM.76
Partial heat recovery watercondensor CU-NIRP01.75RP01.10RP01.20
AC fan with available static pressure up to 150 PaStandard
EC fan with available static pressure up to 300 PaV1CE.10V1CE.20
Rubber vibration dampersKAVG.20
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...