The glove valve has been designed for use in stationary heating, ventilation and
air-conditioning systems and is not allowed to be used outside the specified field
of application, especially in aircraft or in any other airborne means of transport.
Specifications
The globe valve is adjusted by a globe valve actuator. The actuators are connected by a commercially available modulating or 3-point control system and move the valve cone, which acts as a throttling device, into the opening position dictated by the positioning signal. Coupling pipes not included!
Articles
Artikelselectie-assistent
Type
Koelvermogen* [kW]
Verwarmingsvermogen* [kW]
# pijps
AC of EC motor
Artikelnummer
Type
Koelvermogen* [kW]
Verwarmingsvermogen* [kW]
# pijps
AC of EC motor
E-shop
J035509071001
LIGHT-71-NC
6.10
7.60
2
AC
J035509072002
LIGHT-72-NC
9.40
10.40
2
AC
J035509073003
LIGHT-73-NC
10.80
13.50
2
AC
J035509091001
LIGHT-91-NC
6.10
9
4
AC
J035509092002
LIGHT-92-NC
7.10
10.50
4
AC
J035509093003
LIGHT-93-NC
8.60
12.50
4
AC
J035509094003
LIGHT-94-NC
9.90
9.60
4
AC
J035509171001
LIGHT-71-RC
6.10
7.60
2
AC
J035509172002
LIGHT-72-RC
9.40
10.40
2
AC
J035509173003
LIGHT-73-RC
10.80
13.50
2
AC
J035509191001
LIGHT-91-RC
6.10
9
4
AC
J035509192002
LIGHT-92-RC
7.10
10.50
4
AC
J035509193003
LIGHT-93-RC
8.60
12.50
4
AC
J035509194003
LIGHT-94-RC
9.90
9.60
4
AC
Prijzen zijn exclusief decoratiepaneel
* Volgens EUROVENT bij hoogste snelheid
AC-ventilatoren zijn beschikbaar via de website en e-shop
Specifications
DN [mm]
Rp [Inch]
Kvs [m³/h]
ps [kPa]
Stroke [mm]
H411B
15
1/2
0,63
1600
15
H412B
15
1/2
1
1600
15
H413B
15
1/2
1,6
1600
15
H414B
15
1/2
2,5
1600
15
H415B
15
1/2
4
1600
15
H420B
20
3/4
6,3
1600
15
H425B
25
1
10
1600
15
H432B
32
1 1/4
16
1600
15
Technical data
Functional data
Media: Cold and hot water, water with glycol up to max. 50% vol
Medium temperature: 5°C ... 120 °C
Leakage rate: Leakage Class III (DIN EN 1349 and DIN EN 60534-4)
Pipe connectors: External thread in accordance to ISO 228
Closing point: Top
Installation position: Upright to horizontal (in relation to the stem)