Direct driven centrifugal fan
Air performance data
|
|
VMI 7/7-4A M | - | 1700 | 1650 | 1450 | 750 | - | - | - | - | - | - | - | - | - | - | VMI 9/9-6 M | 2800 | 2600 | 2100 | - | - | - | - | - | - | - | - | - | - | - | - | VMI 9/9-4 M | - | - | 3530 | 3375 | 3150 | 2800 | 2525 | 700 | - | - | - | - | - | - | - | VMI 10/10-6 M | - | 3350 | 3175 | 2750 | 350 | - | - | - | - | - | - | - | - | - | - | VMI 12/9-6 M | - | - | - | 4680 | 4150 | 3500 | 860 | - | - | - | - | - | - | - | - | VMI 12/12-6 M | - | - | - | - | 4850 | 2000 | 685 | - | - | - | - | - | - | - | - | VMI 12/12-6 T | - | - | - | 6550 | 5750 | 4680 | 1450 | 935 | - | - | - | - | - | - | - | VMI 15/15-6 T | - | - | - | - | - | - | 9000 | 6625 | 5000 | 1310 | 435 | - | - | - | - |
Attention
The VMI fan may never be used with free inlet. There should be a minimal
counter-pressure as indicated above. Please measure the current at first
starting.
Selection curves
Selection curves
Technical data
|
VMI 7/7-4A M | 1 x 230 | 147 | 1.6 | TSC-1-22 | 40 | 55 | 1420 | 59 | VMI 9/9-6 M | 1 x 230 | 245 | 2.2 | TSC-1-40 | 40 | 55 | 960 | 78 | VMI 9/9-4 M | 1 x 230 | 550 | 4.6 | TSC-1-50 | 40 | 55 | 1420 | 67 | VMI 10/10-6 M | 1 x 230 | 245 | 2.8 | TSC-1-30 | 40 | 44 | 980 | 78 | VMI 12/9-6 M | 1 x 230 | 750 | 5.5 | TSC-1-70 | 40 | 55 | 913 | 79 | VMI 12/12-6 M | 1 x 230 | 750 | 5.6 | TSC-1-70 | 40 | 55 | 899 | 81 | VMI 12/12-6 T | 3 x 230/400 | 1100 | 5.2 / 3 | TSCTK-4-40 / FIS(-C)-13-B / FIS(-C)-44-B | 40 | 44 | 980 | 74 | VMI 15/15-6 T | 3 x 230/400 | 2200 | 8.83 / 5.1 | TSCTK-4-70 / FIS(-C)-13-B / FIS(-C)-44-B | 40 | 44 | 990 | 86 |
- SC = Speed controller
- Tm = Maximum air temperature
- Lpa = Sound pressure level
|