PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

CGW-IU A1 • A2W heat pumps R32 hydromodule

Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating and cooling of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.

Brand

  • R-AQUA

Application

  • Heating of new or existing houses
  • Heating by means of radiators, convectors or floor, wall or ceiling heating
  • Cooling by means of convectors, floor, wall or ceiling cooling
  • Production of domestic hot water, provided a hot water heater is installed

Composition

  • 3-way valve
  • Communication cable included
  • High efficiency plate heat exchanger
  • Energy-efficient circulation pump
  • Colour touch screen controller (wired)

  • Expansion vessel (10 liters)
  • Safety valve (3 bar)
  • Electrical backup heater
  • Water pressure sensor

Refrigerant

  • R32

Specifications

  • Split system
  • 1 device for heating, cooling and domestic hot water
    • Heating assured at outside temperatures down to -25°C
    • Water temperature up to 55°C at outside temperatures down to -10°C
  • A+++ at 35°C water temperature
  • Bivalent setup possible
      • The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.

  • Standard equipped with WiFi
  • Standard equipped with Modbus interface
  • Easy installation
  • EUROVENT EN 14511 and EN 14825 certification
  • Keymark certification

Accessories

  • Room Thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
  • Smart Grid module, type SMART GRID
  • Cascade module, type CASCADE
  • Buffer tank, type BTE 60, BTE 100
  • Deaerator, type AAS

  • Magnetic dirt separator, type ADS

  • Differential pressure regulator, type DPC

  • Filling set, type WFS

  • Expansion vessel for heating, type HEV

  • Expansion vessel console, type EVC

  • Protector, type PAB

  • Coding plug for permanently disabling the cooling function, type COD-IU-H

  • Start-up is strongly recommended, type XSTARTUPJ

Water filter, safety group and expansion vessel MUST be provided on site.

Applicable outdoor units

  • Outdoor unit, Type CGW-OU A1

Applicable boiler

  • Domestic hot water heater 200 liters, type SANI-EM 200
  • Domestic hot water heater 300 liters, type SANI-EM 300, SANI 300+
  • Domestic hot water heater 500 liters, type SANI-EM 500, SANI 500+

Startup

  • Start-up by CAIROX BELGIUM strongly recommended

Notes

The 3 way valve is integrated to the indoor unit CGW-IU.

Technical data

Indoor unitCGW-IU 06 A1CGW-IU 08 A1CGW-IU 10 A1CGW-IU 12 A1CGW-IU 14 A1CGW-IU 16 A1
Corresponding outdoor unitCGW-OU 06 A1CGW-OU 08 A1CGW-OU 10 A1CGW-OU 12 A1CGW-OU 14 A1CGW-OU 16 A1
Heating capacity A7/W35kW6,008,0010,0012,0014,0015,5
COP A7/W35 5,004,974,765,004,704,50
Heating capacity A7/W45kW5,808,009,8512,4014,4816,09
COP A7/W45 3,823,863,673,773,683,62
Heating capacity A2/W35kW5,196,567,679,6011,2013,13
COP A2/W35 3,713,693,533,423,343,74
Heating capacity A2/W45kW5,066,407,489,3610,9213,13
COP A2/W45 2,972,952,832,742,673,13
Heating capacity A-7/W35kW4,285,416,337,688,9610,81
COP A-7/W35 2,932,922,792,702,632,74
Heating capacity A-7/W45kW4,155,256,147,448,6810,81
COP A-7/W45 2,342,332,232,162,112,21
Heating capacity A-10/W35kW3,894,925,756,727,8410,04
Heating capacity A-10/W45kW3,764,765,566,487,5610,04
SCOP W35/W55 4,53/3,254,60/3,304,60/3,254,63/3,234,65/3,504,60/3,50
Seasonal efficiency ηs heat pump W35/W55%179/127181/129181/127182/126183/137181/137
Annual consumption heat pump W35/W55kWh2729/31693149/43714038/50914967/69855535/80455886/8045
Energy class W35/W55 A+++/A++

Power supply

V / Ph / Hz230/1/50
Refrigerant (GWP) R32 (675)
Refrigerant pipes (liquid - gas)inch1/4 - 1/21/4 - 5/8
Hydraulic connections (supply - return)inch1
Outgoing water temperaturesHeating°C20 ~ 60
Cooling°C7 ~ 25
DHW°C40 ~ 80
ComponentsPumpType-High-efficiency pump
Regulation-Electronic - continuous control
Capacity (min-max)W3 ~ 95
Flow rate (min)l/h650870870115011501150
Flow rate (nom)l/h103013801710206024102660
Expansion vesselVolume*l10
Pressure (max)bar3
Pre-pressurebar1
Backup electric heatingType-Wet
Material-Incoloy825
Regulation-Automatic
Number of steps-2
CapacitykW36
CombinationkW1,5 + 1,53 + 3
Heat exchangerType-Plate heat exchanger
Number-1
Sound pressure**dB (A)29
Power cable section indoor unitmm²3G2,53G6
Automatic fuse (slow)A2032
DimensionsUnit (LxDxH)mm460x320x860
Weightkg62
Specifications and design can change without notice for further improvements
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be