This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating and cooling of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.
Brand
R-AQUA
Application
Heating of new or existing houses
Heating by means of radiators, convectors or floor, wall or ceiling heating
Cooling by means of convectors, floor, wall or ceiling cooling
Production of
domestic hot water, provided a hot water heater is installed
Composition
3-way valve
Communication cable included
High efficiency plate heat exchanger
Energy-efficient circulation pump
Colour touch screen controller
(wired)
Expansion vessel (10 liters)
Safety valve (3 bar)
Electrical backup heater
Water pressure sensor
Refrigerant
R32
Specifications
Split system
1 device for heating, cooling and domestic hot water
Heating assured at outside temperatures down to -25°C
Water temperature up to 55°C at outside temperatures down to -10°C
A+++ at 35°C water temperature
Bivalent setup possible
The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.
Standard equipped with WiFi
Standard equipped with Modbus interface
Easy installation
EUROVENT EN 14511 and EN 14825 certification
Keymark certification
Accessories
Room Thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
Smart Grid module, type SMART GRID
Cascade module, type CASCADE
Buffer tank, type BTE 60, BTE 100
Deaerator, type AAS
Magnetic dirt separator, type ADS
Differential pressure regulator, type DPC
Filling set, type WFS
Expansion vessel for heating, type HEV
Expansion vessel console, type EVC
Protector, type PAB
Coding plug
for permanently disabling the cooling function, type COD-IU-H
Start-up is strongly recommended, type XSTARTUPJ
Water filter, safety group and expansion vessel MUST be provided on site.
Applicable outdoor units
Outdoor unit, TypeCGW-OU A1
Applicable boiler
Domestic hot water heater 200 liters, type SANI-EM 200
Domestic hot water heater 300 liters, type SANI-EM 300, SANI 300+
Domestic hot water heater 500 liters, type SANI-EM 500, SANI 500+
Articles
Article selection assistant
Type
Type of regulation
Size
Article number
Type
Type of regulation
Size
E-shop
Spare parts
I100720000080
GTDHRV 9008 PBC -W
BASIC
4
I100720000100
GTDHRV 9010 PBC -W
BASIC
4
I100720000160
GTDHRV 9016 PBC -W
BASIC
5
I100720000230
GTDHRV 9023 PBC -W
BASIC
6
I100720000350
GTDHRV 9035 PBC -W
BASIC
7
I100720000480
GTDHRV 9048 PBC -W
BASIC
8
I100720000700
GTDHRV 9070 PBC -D
BASIC
-
I100720010080
GTDHRV 9008 PBCL -W
LOBBY EC
4
I100720010100
GTDHRV 9010 PBCL -W
LOBBY EC
4
I100720010160
GTDHRV 9016 PBCL -W
LOBBY EC
5
I100720010230
GTDHRV 9023 PBCL -W
LOBBY EC
6
I100720010350
GTDHRV 9035 PBCL -W
LOBBY EC
7
I100720010480
GTDHRV 9048 PBCL -W
LOBBY EC
8
I100720010700
GTDHRV 9070 PBCL -D
LOBBY EC
-
I100720020080
GTDHRV 9008 PBCD -W
DIVA EC
4
I100720020100
GTDHRV 9010 PBCD -W
DIVA EC
4
I100720020160
GTDHRV 9016 PBCD -W
DIVA EC
5
I100720020230
GTDHRV 9023 PBCD -W
DIVA EC
6
I100720020350
GTDHRV 9035 PBCD -W
DIVA EC
7
I100720020480
GTDHRV 9048 PBCD -W
DIVA EC
8
I100720020700
GTDHRV 9070 PBCD -D
DIVA EC
-
I100720030100
GTDHRV 9010 PBCM -W
MAC2 EC
4
I100720030160
GTDHRV 9016 PBCM -W
MAC2 EC
5
I100720030230
GTDHRV 9023 PBCM -W
MAC2 EC
6
I100720030350
GTDHRV 9035 PBCM -W
MAC2 EC
7
I100720030480
GTDHRV 9048 PBCM -W
MAC2 EC
8
I100720030700
GTDHRV 9070 PBCM -D
MAC2 EC
-
I100720040100
GTDHRV 9010 PBCQ -W
QUATRO EC
4
I100720040160
GTDHRV 9016 PBCQ -W
QUATRO EC
5
I100720040230
GTDHRV 9023 PBCQ -W
QUATRO EC
6
I100720040350
GTDHRV 9035 PBCQ -W
QUATRO EC
7
I100720040480
GTDHRV 9048 PBCQ -W
QUATRO EC
8
I100720040700
GTDHRV 9070 PBCQ -D
QUATRO EC
-
I100730000080
GTDHRV 9008 PBE -W
BASIC
4
I100730000100
GTDHRV 9010 PBE -W
BASIC
4
I100730000160
GTDHRV 9016 PBE037 -W
BASIC
5
I100730000161
GTDHRV 9016 PBE052 -W
BASIC
5
I100730000230
GTDHRV 9023 PBE037 -W
BASIC
6
I100730000231
GTDHRV 9023 PBE067 -W
BASIC
6
I100730000350
GTDHRV 9035 PBE067 -W
BASIC
7
I100730000351
GTDHRV 9035 PBE137 -W
BASIC
7
I100730000480
GTDHRV 9048 PBE067 -W
BASIC
8
I100730000481
GTDHRV 9048 PBE137 -W
BASIC
8
I100730000700
GTDHRV 9070 PBE105 -D
BASIC
-
I100730000701
GTDHRV 9070 PBE157 -D
BASIC
-
I100730010080
GTDHRV 9008 PBEL -W
LOBBY EC
4
I100730010100
GTDHRV 9010 PBEL -W
LOBBY EC
4
I100730010160
GTDHRV 9016 PBE037L -W
LOBBY EC
5
I100730010161
GTDHRV 9016 PBE052L -W
LOBBY EC
5
I100730010230
GTDHRV 9023 PBE037L -W
LOBBY EC
6
I100730010231
GTDHRV 9023 PBE067L -W
LOBBY EC
6
I100730010350
GTDHRV 9035 PBE067L -W
LOBBY EC
7
I100730010351
GTDHRV 9035 PBE137L -W
LOBBY EC
7
I100730010480
GTDHRV 9048 PBE067L -W
LOBBY EC
8
I100730010481
GTDHRV 9048 PBE137L -W
LOBBY EC
8
I100730010700
GTDHRV 9070 PBE105L -D
LOBBY EC
-
I100730010701
GTDHRV 9070 PBE157L -D
LOBBY EC
-
I100730020080
GTDHRV 9008 PBED -W
DIVA EC
4
I100730020100
GTDHRV 9010 PBED -W
DIVA EC
4
I100730020160
GTDHRV 9016 PBE037D -W
DIVA EC
5
I100730020161
GTDHRV 9016 PBE052D -W
DIVA EC
5
I100730020230
GTDHRV 9023 PBE037D -W
DIVA EC
6
I100730020231
GTDHRV 9023 PBE067D -W
DIVA EC
6
I100730020350
GTDHRV 9035 PBE067D -W
DIVA EC
7
I100730020351
GTDHRV 9035 PBE137D -W
DIVA EC
7
I100730020480
GTDHRV 9048 PBE067D -W
DIVA EC
8
I100730020481
GTDHRV 9048 PBE137D -W
DIVA EC
8
I100730020700
GTDHRV 9070 PBE105D -D
DIVA EC
-
I100730020701
GTDHRV 9070 PBE157D -D
DIVA EC
-
I100730030100
GTDHRV 9010 PBEM -W
MAC2 EC
4
I100730030160
GTDHRV 9016 PBE037M -W
MAC2 EC
5
I100730030161
GTDHRV 9016 PBE052M -W
MAC2 EC
5
I100730030230
GTDHRV 9023 PBE037M -W
MAC2 EC
6
I100730030231
GTDHRV 9023 PBE067M -W
MAC2 EC
6
I100730030350
GTDHRV 9035 PBE067M -W
MAC2 EC
7
I100730030351
GTDHRV 9035 PBE137M -W
MAC2 EC
7
I100730030480
GTDHRV 9048 PBE067M -W
MAC2 EC
8
I100730030481
GTDHRV 9048 PBE137M -W
MAC2 EC
8
I100730030700
GTDHRV 9070 PBE105M -D
MAC2 EC
-
I100730030701
GTDHRV 9070 PBE157M -D
MAC2 EC
-
I100730040100
GTDHRV 9010 PBEQ -W
QUATRO EC
4
I100730040160
GTDHRV 9016 PBE037Q -W
QUATRO EC
5
I100730040161
GTDHRV 9016 PBE052Q -W
QUATRO EC
5
I100730040230
GTDHRV 9023 PBE037Q -W
QUATRO EC
6
I100730040231
GTDHRV 9023 PBE067Q -W
QUATRO EC
6
I100730040350
GTDHRV 9035 PBE067Q -W
QUATRO EC
7
I100730040351
GTDHRV 9035 PBE137Q -W
QUATRO EC
7
I100730040480
GTDHRV 9048 PBE067Q -W
QUATRO EC
8
I100730040481
GTDHRV 9048 PBE137Q -W
QUATRO EC
8
I100730040700
GTDHRV 9070 PBE105Q -D
QUATRO EC
-
I100730040701
GTDHRV 9070 PBE157Q -D
QUATRO EC
-
=> Stock product central warehouse, except sales
Other configurations on request.
Startup
Start-up by CAIROX BELGIUM strongly recommended
Notes
The 3 way valve is integrated to the indoor unit CGW-IU.
Technical data
Indoor unit
CGW-IU 06 A1
CGW-IU 08 A1
CGW-IU 10 A1
CGW-IU 12 A1
CGW-IU 14 A1
CGW-IU 16 A1
Corresponding outdoor unit
CGW-OU 06 A1
CGW-OU 08 A1
CGW-OU 10 A1
CGW-OU 12 A1
CGW-OU 14 A1
CGW-OU 16 A1
Heating capacity A7/W35
kW
6,00
8,00
10,00
12,00
14,00
15,5
COP A7/W35
5,00
4,97
4,76
5,00
4,70
4,50
Heating capacity A7/W45
kW
5,80
8,00
9,85
12,40
14,48
16,09
COP A7/W45
3,82
3,86
3,67
3,77
3,68
3,62
Heating capacity A2/W35
kW
5,19
6,56
7,67
9,60
11,20
13,13
COP A2/W35
3,71
3,69
3,53
3,42
3,34
3,74
Heating capacity A2/W45
kW
5,06
6,40
7,48
9,36
10,92
13,13
COP A2/W45
2,97
2,95
2,83
2,74
2,67
3,13
Heating capacity A-7/W35
kW
4,28
5,41
6,33
7,68
8,96
10,81
COP A-7/W35
2,93
2,92
2,79
2,70
2,63
2,74
Heating capacity A-7/W45
kW
4,15
5,25
6,14
7,44
8,68
10,81
COP A-7/W45
2,34
2,33
2,23
2,16
2,11
2,21
Heating capacity A-10/W35
kW
3,89
4,92
5,75
6,72
7,84
10,04
Heating capacity A-10/W45
kW
3,76
4,76
5,56
6,48
7,56
10,04
SCOP W35/W55
4,53/3,25
4,60/3,30
4,60/3,25
4,63/3,23
4,65/3,50
4,60/3,50
Seasonal efficiency ηs heat pump W35/W55
%
179/127
181/129
181/127
182/126
183/137
181/137
Annual consumption heat pump W35/W55
kWh
2729/3169
3149/4371
4038/5091
4967/6985
5535/8045
5886/8045
Energy class W35/W55
A+++/A++
Power
supply
V / Ph / Hz
230/1/50
Refrigerant (GWP)
R32 (675)
Refrigerant pipes (liquid - gas)
inch
1/4 - 1/2
1/4 - 5/8
Hydraulic connections (supply - return)
inch
1
Outgoing water temperatures
Heating
°C
20 ~ 60
Cooling
°C
7 ~ 25
DHW
°C
40 ~ 80
Components
Pump
Type
-
High-efficiency pump
Regulation
-
Electronic - continuous control
Capacity (min-max)
W
3 ~ 95
Flow rate (min)
l/h
650
870
870
1150
1150
1150
Flow rate (nom)
l/h
1030
1380
1710
2060
2410
2660
Expansion vessel
Volume*
l
10
Pressure (max)
bar
3
Pre-pressure
bar
1
Backup electric heating
Type
-
Wet
Material
-
Incoloy825
Regulation
-
Automatic
Number of steps
-
2
Capacity
kW
3
6
Combination
kW
1,5 + 1,5
3 + 3
Heat exchanger
Type
-
Plate heat exchanger
Number
-
1
Sound pressure**
dB (A)
29
Power cable section indoor unit
mm²
3G2,5
3G6
Automatic fuse (slow)
A
20
32
Dimensions
Unit (LxDxH)
mm
460x320x860
Weight
kg
62
Specifications and design can change without notice for further improvements
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber