PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

CGW-IU A1 • A2W heat pumps R32 hydromodule

Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating and cooling of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.

Brand

  • R-AQUA

Application

  • Heating of new or existing houses
  • Heating by means of radiators, convectors or floor, wall or ceiling heating
  • Cooling by means of convectors, floor, wall or ceiling cooling
  • Production of domestic hot water, provided a hot water heater is installed

Composition

  • 3-way valve
  • Communication cable included
  • High efficiency plate heat exchanger
  • Energy-efficient circulation pump
  • Colour touch screen controller (wired)

  • Expansion vessel (10 liters)
  • Safety valve (3 bar)
  • Electrical backup heater
  • Water pressure sensor

Refrigerant

  • R32

Specifications

  • Split system
  • 1 device for heating, cooling and domestic hot water
    • Heating assured at outside temperatures down to -25°C
    • Water temperature up to 55°C at outside temperatures down to -10°C
  • A+++ at 35°C water temperature
  • Bivalent setup possible
      • The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.

  • Standard equipped with WiFi
  • Standard equipped with Modbus interface
  • Easy installation
  • EUROVENT EN 14511 and EN 14825 certification
  • Keymark certification

Accessories

  • Room Thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
  • Smart Grid module, type SMART GRID
  • Cascade module, type CASCADE
  • Buffer tank, type BTE 60, BTE 100
  • Deaerator, type AAS

  • Magnetic dirt separator, type ADS

  • Differential pressure regulator, type DPC

  • Filling set, type WFS

  • Expansion vessel for heating, type HEV

  • Expansion vessel console, type EVC

  • Protector, type PAB

  • Coding plug for permanently disabling the cooling function, type COD-IU-H

  • Start-up is strongly recommended, type XSTARTUPJ

Water filter, safety group and expansion vessel MUST be provided on site.

Applicable outdoor units

  • Outdoor unit, Type CGW-OU A1

Applicable boiler

  • Domestic hot water heater 200 liters, type SANI-EM 200
  • Domestic hot water heater 300 liters, type SANI-EM 300, SANI 300+
  • Domestic hot water heater 500 liters, type SANI-EM 500, SANI 500+

Articles

Article selection assistant
Type
Type of regulation
Size
Article number Type Type of regulation Size E-shop Spare parts
I100720000080 GTDHRV 9008 PBC -W BASIC 4
I100720000100 GTDHRV 9010 PBC -W BASIC 4
I100720000160 GTDHRV 9016 PBC -W BASIC 5
I100720000230 GTDHRV 9023 PBC -W BASIC 6
I100720000350 GTDHRV 9035 PBC -W BASIC 7
I100720000480 GTDHRV 9048 PBC -W BASIC 8
I100720000700 GTDHRV 9070 PBC -D BASIC -
I100720010080 GTDHRV 9008 PBCL -W LOBBY EC 4
I100720010100 GTDHRV 9010 PBCL -W LOBBY EC 4
I100720010160 GTDHRV 9016 PBCL -W LOBBY EC 5
I100720010230 GTDHRV 9023 PBCL -W LOBBY EC 6
I100720010350 GTDHRV 9035 PBCL -W LOBBY EC 7
I100720010480 GTDHRV 9048 PBCL -W LOBBY EC 8
I100720010700 GTDHRV 9070 PBCL -D LOBBY EC -
I100720020080 GTDHRV 9008 PBCD -W DIVA EC 4
I100720020100 GTDHRV 9010 PBCD -W DIVA EC 4
I100720020160 GTDHRV 9016 PBCD -W DIVA EC 5
I100720020230 GTDHRV 9023 PBCD -W DIVA EC 6
I100720020350 GTDHRV 9035 PBCD -W DIVA EC 7
I100720020480 GTDHRV 9048 PBCD -W DIVA EC 8
I100720020700 GTDHRV 9070 PBCD -D DIVA EC -
I100720030100 GTDHRV 9010 PBCM -W MAC2 EC 4
I100720030160 GTDHRV 9016 PBCM -W MAC2 EC 5
I100720030230 GTDHRV 9023 PBCM -W MAC2 EC 6
I100720030350 GTDHRV 9035 PBCM -W MAC2 EC 7
I100720030480 GTDHRV 9048 PBCM -W MAC2 EC 8
I100720030700 GTDHRV 9070 PBCM -D MAC2 EC -
I100720040100 GTDHRV 9010 PBCQ -W QUATRO EC 4
I100720040160 GTDHRV 9016 PBCQ -W QUATRO EC 5
I100720040230 GTDHRV 9023 PBCQ -W QUATRO EC 6
I100720040350 GTDHRV 9035 PBCQ -W QUATRO EC 7
I100720040480 GTDHRV 9048 PBCQ -W QUATRO EC 8
I100720040700 GTDHRV 9070 PBCQ -D QUATRO EC -
I100730000080 GTDHRV 9008 PBE -W BASIC 4
I100730000100 GTDHRV 9010 PBE -W BASIC 4
I100730000160 GTDHRV 9016 PBE037 -W BASIC 5
I100730000161 GTDHRV 9016 PBE052 -W BASIC 5
I100730000230 GTDHRV 9023 PBE037 -W BASIC 6
I100730000231 GTDHRV 9023 PBE067 -W BASIC 6
I100730000350 GTDHRV 9035 PBE067 -W BASIC 7
I100730000351 GTDHRV 9035 PBE137 -W BASIC 7
I100730000480 GTDHRV 9048 PBE067 -W BASIC 8
I100730000481 GTDHRV 9048 PBE137 -W BASIC 8
I100730000700 GTDHRV 9070 PBE105 -D BASIC -
I100730000701 GTDHRV 9070 PBE157 -D BASIC -
I100730010080 GTDHRV 9008 PBEL -W LOBBY EC 4
I100730010100 GTDHRV 9010 PBEL -W LOBBY EC 4
I100730010160 GTDHRV 9016 PBE037L -W LOBBY EC 5
I100730010161 GTDHRV 9016 PBE052L -W LOBBY EC 5
I100730010230 GTDHRV 9023 PBE037L -W LOBBY EC 6
I100730010231 GTDHRV 9023 PBE067L -W LOBBY EC 6
I100730010350 GTDHRV 9035 PBE067L -W LOBBY EC 7
I100730010351 GTDHRV 9035 PBE137L -W LOBBY EC 7
I100730010480 GTDHRV 9048 PBE067L -W LOBBY EC 8
I100730010481 GTDHRV 9048 PBE137L -W LOBBY EC 8
I100730010700 GTDHRV 9070 PBE105L -D LOBBY EC -
I100730010701 GTDHRV 9070 PBE157L -D LOBBY EC -
I100730020080 GTDHRV 9008 PBED -W DIVA EC 4
I100730020100 GTDHRV 9010 PBED -W DIVA EC 4
I100730020160 GTDHRV 9016 PBE037D -W DIVA EC 5
I100730020161 GTDHRV 9016 PBE052D -W DIVA EC 5
I100730020230 GTDHRV 9023 PBE037D -W DIVA EC 6
I100730020231 GTDHRV 9023 PBE067D -W DIVA EC 6
I100730020350 GTDHRV 9035 PBE067D -W DIVA EC 7
I100730020351 GTDHRV 9035 PBE137D -W DIVA EC 7
I100730020480 GTDHRV 9048 PBE067D -W DIVA EC 8
I100730020481 GTDHRV 9048 PBE137D -W DIVA EC 8
I100730020700 GTDHRV 9070 PBE105D -D DIVA EC -
I100730020701 GTDHRV 9070 PBE157D -D DIVA EC -
I100730030100 GTDHRV 9010 PBEM -W MAC2 EC 4
I100730030160 GTDHRV 9016 PBE037M -W MAC2 EC 5
I100730030161 GTDHRV 9016 PBE052M -W MAC2 EC 5
I100730030230 GTDHRV 9023 PBE037M -W MAC2 EC 6
I100730030231 GTDHRV 9023 PBE067M -W MAC2 EC 6
I100730030350 GTDHRV 9035 PBE067M -W MAC2 EC 7
I100730030351 GTDHRV 9035 PBE137M -W MAC2 EC 7
I100730030480 GTDHRV 9048 PBE067M -W MAC2 EC 8
I100730030481 GTDHRV 9048 PBE137M -W MAC2 EC 8
I100730030700 GTDHRV 9070 PBE105M -D MAC2 EC -
I100730030701 GTDHRV 9070 PBE157M -D MAC2 EC -
I100730040100 GTDHRV 9010 PBEQ -W QUATRO EC 4
I100730040160 GTDHRV 9016 PBE037Q -W QUATRO EC 5
I100730040161 GTDHRV 9016 PBE052Q -W QUATRO EC 5
I100730040230 GTDHRV 9023 PBE037Q -W QUATRO EC 6
I100730040231 GTDHRV 9023 PBE067Q -W QUATRO EC 6
I100730040350 GTDHRV 9035 PBE067Q -W QUATRO EC 7
I100730040351 GTDHRV 9035 PBE137Q -W QUATRO EC 7
I100730040480 GTDHRV 9048 PBE067Q -W QUATRO EC 8
I100730040481 GTDHRV 9048 PBE137Q -W QUATRO EC 8
I100730040700 GTDHRV 9070 PBE105Q -D QUATRO EC -
I100730040701 GTDHRV 9070 PBE157Q -D QUATRO EC -
=> Stock product central warehouse, except sales
Other configurations on request.

Startup

  • Start-up by CAIROX BELGIUM strongly recommended

Notes

The 3 way valve is integrated to the indoor unit CGW-IU.

Technical data

Indoor unitCGW-IU 06 A1CGW-IU 08 A1CGW-IU 10 A1CGW-IU 12 A1CGW-IU 14 A1CGW-IU 16 A1
Corresponding outdoor unitCGW-OU 06 A1CGW-OU 08 A1CGW-OU 10 A1CGW-OU 12 A1CGW-OU 14 A1CGW-OU 16 A1
Heating capacity A7/W35kW6,008,0010,0012,0014,0015,5
COP A7/W35 5,004,974,765,004,704,50
Heating capacity A7/W45kW5,808,009,8512,4014,4816,09
COP A7/W45 3,823,863,673,773,683,62
Heating capacity A2/W35kW5,196,567,679,6011,2013,13
COP A2/W35 3,713,693,533,423,343,74
Heating capacity A2/W45kW5,066,407,489,3610,9213,13
COP A2/W45 2,972,952,832,742,673,13
Heating capacity A-7/W35kW4,285,416,337,688,9610,81
COP A-7/W35 2,932,922,792,702,632,74
Heating capacity A-7/W45kW4,155,256,147,448,6810,81
COP A-7/W45 2,342,332,232,162,112,21
Heating capacity A-10/W35kW3,894,925,756,727,8410,04
Heating capacity A-10/W45kW3,764,765,566,487,5610,04
SCOP W35/W55 4,53/3,254,60/3,304,60/3,254,63/3,234,65/3,504,60/3,50
Seasonal efficiency ηs heat pump W35/W55%179/127181/129181/127182/126183/137181/137
Annual consumption heat pump W35/W55kWh2729/31693149/43714038/50914967/69855535/80455886/8045
Energy class W35/W55 A+++/A++

Power supply

V / Ph / Hz230/1/50
Refrigerant (GWP) R32 (675)
Refrigerant pipes (liquid - gas)inch1/4 - 1/21/4 - 5/8
Hydraulic connections (supply - return)inch1
Outgoing water temperaturesHeating°C20 ~ 60
Cooling°C7 ~ 25
DHW°C40 ~ 80
ComponentsPumpType-High-efficiency pump
Regulation-Electronic - continuous control
Capacity (min-max)W3 ~ 95
Flow rate (min)l/h650870870115011501150
Flow rate (nom)l/h103013801710206024102660
Expansion vesselVolume*l10
Pressure (max)bar3
Pre-pressurebar1
Backup electric heatingType-Wet
Material-Incoloy825
Regulation-Automatic
Number of steps-2
CapacitykW36
CombinationkW1,5 + 1,53 + 3
Heat exchangerType-Plate heat exchanger
Number-1
Sound pressure**dB (A)29
Power cable section indoor unitmm²3G2,53G6
Automatic fuse (slow)A2032
DimensionsUnit (LxDxH)mm460x320x860
Weightkg62
Specifications and design can change without notice for further improvements
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...