Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.
The integrated water heater (185L) is made of enamelled steel to protect against corrosion on the inside. A anode will protect the tank against ionization.
Brand
R-AQUA
Application
Heating of new or existing houses
Heating by means of radiators, convectors or floor, wall or ceiling heating
Cooling by means of convectors, floor, wall or ceiling cooling
Heating of domestic water
Composition
3-way valve
Communication cable included
High efficiency plate heat exchangers
Energy-efficient circulation pumps
Integrated
water heater with thermal stratification (185 liters)
Colour touch screen controller
(wired)
Expansion vessel (10 liters)
Safety valve (3 bar)
Electrical backup heater
Electrical backup heater domestic water
electronic anode
Water pressure sensor
Refrigerant
R32
Specifications
Split system
1 device for heating, cooling and domestic hot water
Heating assured at outside temperatures down to -25°C
Water temperature up to 55°C at outside temperatures down to -10°C
A+++ at 35°C water temperature
Bivalent setup possible
The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.
Standard equipped with WiFi
Standard equipped with Modbus interface
Easy installation
EUROVENT EN 14511 and EN 14825 certification
Keymark certification
Accessories
Room thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
Smart Grid module, type SMART GRID
Buffer tank, type BTE 60, BTE 100
Deaerator, type AAS
Magnetic dirt separator, type ADS
Differential pressure regulator, type DPC
Filling set, type WFS
Expansion vessel for heating, type HEV
Expansion vessel console, type EVC
Protector, type PAB
Safety group, type PSG
Siphon for pressure safety group, type SSG
Expansion vessel for sanitary water, type SEV
Connection kit for sanitary expansion vessel, type EVC SAN
Pressure regulator, type PRV
Coding plug
for permanently disabling the cooling function, type COD-ID-H
Start-up is strongly recommended, type XSTARTUPJ
Water filter, safety group and expansion vessel MUST be provided on site.
Applicable outdoor units
Outdoor unit, type CGW-OU M1
Articles
Article selection assistant
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
Article number
Type
# pipes
AC or EC engine
Horizontal or vertical
Hydraulic connection
E-shop
J035521030010
FRESH-ECM-H-1/L/2P
2
EC
Horizontal
Left
J035521030012
FRESH-ECM-V-1/L/2P
2
EC
Vertical
Left
J035521030020
FRESH-ECM-H-2/L/2P
2
EC
Horizontal
Left
J035521030022
FRESH-ECM-V-2/L/2P
2
EC
Vertical
Left
J035521030030
FRESH-ECM-H-3/L/2P
2
EC
Horizontal
Left
J035521030032
FRESH-ECM-V-3/L/2P
2
EC
Vertical
Left
J035521030040
FRESH-ECM-H-4/L/2P
2
EC
Horizontal
Left
J035521030042
FRESH-ECM-V-4/L/2P
2
EC
Vertical
Left
J035521030050
FRESH-ECM-H-5/L/2P
2
EC
Horizontal
Left
J035521030052
FRESH-ECM-V-5/L/2P
2
EC
Vertical
Left
J035521030060
FRESH-ECM-H-6/L/2P
2
EC
Horizontal
Left
J035521030062
FRESH-ECM-V-6/L/2P
2
EC
Vertical
Left
J035521030070
FRESH-ECM-H-7/L/2P
2
EC
Horizontal
Left
J035521030072
FRESH-ECM-V-7/L/2P
2
EC
Vertical
Left
J035521031010
FRESH-ECM-H-1/R/2P
2
EC
Horizontal
Right
J035521031012
FRESH-ECM-V-1/R/2P
2
EC
Vertical
Right
J035521031020
FRESH-ECM-H-2/R/2P
2
EC
Horizontal
Right
J035521031022
FRESH-ECM-V-2/R/2P
2
EC
Vertical
Right
J035521031030
FRESH-ECM-H-3/R/2P
2
EC
Horizontal
Right
J035521031032
FRESH-ECM-V-3/R/2P
2
EC
Vertical
Right
J035521031040
FRESH-ECM-H-4/R/2P
2
EC
Horizontal
Right
J035521031042
FRESH-ECM-V-4/R/2P
2
EC
Vertical
Right
J035521031050
FRESH-ECM-H-5/R/2P
2
EC
Horizontal
Right
J035521031052
FRESH-ECM-V-5/R/2P
2
EC
Vertical
Right
J035521031060
FRESH-ECM-H-6/R/2P
2
EC
Horizontal
Right
J035521031062
FRESH-ECM-V-6/R/2P
2
EC
Vertical
Right
J035521031070
FRESH-ECM-H-7/R/2P
2
EC
Horizontal
Right
J035521031072
FRESH-ECM-V-7/R/2P
2
EC
Vertical
Right
J035521032010
FRESH-ECM-H-1/L/4P
4
EC
Horizontal
Left
J035521032012
FRESH-ECM-V-1/L/4P
4
EC
Vertical
Left
J035521032020
FRESH-ECM-H-2/L/4P
4
EC
Horizontal
Left
J035521032022
FRESH-ECM-V-2/L/4P
4
EC
Vertical
Left
J035521032030
FRESH-ECM-H-3/L/4P
4
EC
Horizontal
Left
J035521032032
FRESH-ECM-V-3/L/4P
4
EC
Vertical
Left
J035521032040
FRESH-ECM-H-4/L/4P
4
EC
Horizontal
Left
J035521032042
FRESH-ECM-V-4/L/4P
4
EC
Vertical
Left
J035521032050
FRESH-ECM-H-5/L/4P
4
EC
Horizontal
Left
J035521032052
FRESH-ECM-V-5/L/4P
4
EC
Vertical
Left
J035521032060
FRESH-ECM-H-6/L/4P
4
EC
Horizontal
Left
J035521032062
FRESH-ECM-V-6/L/4P
4
EC
Vertical
Left
J035521032070
FRESH-ECM-H-7/L/4P
4
EC
Horizontal
Left
J035521032072
FRESH-ECM-V-7/L/4P
4
EC
Vertical
Left
J035521033010
FRESH-ECM-H-1/R/4P
4
EC
Horizontal
Right
J035521033012
FRESH-ECM-V-1/R/4P
4
EC
Vertical
Right
J035521033020
FRESH-ECM-H-2/R/4P
4
EC
Horizontal
Right
J035521033022
FRESH-ECM-V-2/R/4P
4
EC
Vertical
Right
J035521033030
FRESH-ECM-H-3/R/4P
4
EC
Horizontal
Right
J035521033032
FRESH-ECM-V-3/R/4P
4
EC
Vertical
Right
J035521033040
FRESH-ECM-H-4/R/4P
4
EC
Horizontal
Right
J035521033042
FRESH-ECM-V-4/R/4P
4
EC
Vertical
Right
J035521033050
FRESH-ECM-H-5/R/4P
4
EC
Horizontal
Right
J035521033052
FRESH-ECM-V-5/R/4P
4
EC
Vertical
Right
J035521033060
FRESH-ECM-H-6/R/4P
4
EC
Horizontal
Right
J035521033062
FRESH-ECM-V-6/R/4P
4
EC
Vertical
Right
J035521033070
FRESH-ECM-H-7/R/4P
4
EC
Horizontal
Right
J035521033072
FRESH-ECM-V-7/R/4P
4
EC
Vertical
Right
Startup
Start-up by CAIROX BELGIUM strongly recommended
Technical data
Indoor unit
CGW-ID 12 M1
CGW-ID 14 M1
CGW-ID 16 M1
Corresponding outdoor unit
CGW-OU 12 M1
CGW-OU 14 M1
CGW-OU 16 M1
Heating capacity A7/W35
kW
12,00
14,00
15,50
COP A7/W35
5,00
4,70
4,51
Heating capacity A7/W45
kW
12,29
14,44
16,13
COP A7/W45
3,98
3,98
3,88
Heating capacity A2/W35
kW
9,60
11,20
12,32
COP A2/W35
3,42
3,30
3,23
Heating capacity A2/W45
kW
9,36
10,92
12,01
COP A2/W45
2,74
2,64
2,58
Heating capacity A-7/W35
kW
7,92
9,24
10,16
COP A-7/W35
2,70
2,60
2,55
Heating capacity A-7/W45
kW
7,68
8,96
9,86
COP A-7/W45
2,16
2,08
2,04
Heating capacity A-10/W35
kW
7,20
8,40
9,24
Heating capacity A-10/W45
kW
6,96
8,12
8,93
SCOP W35/W55
4,48/3,23
4,45/3,35
4,45/3,35
Seasonal efficiency ηs heat pump W35/W55
%
176/126
175/131
175/131
Annual energy consumption heat pump W35/W55
kWh
5065/7028
5552/7958
6027/7958
Energy class heat pump W35/W55
A+++/A++
Seasonal efficiency ηs DHW W55
%
112
112
112
Annual energy consumption DHW W55
kWh
915
915
915
Energy class DHW
A
Power
supply
V / Ph / Hz
400/3/50
Refrigerant (GWP)
R32 (675)
Refrigerant pipes (liquid - gas)
inch
1/4 - 5/8
Hydraulic connections (supply - return)
inch
1
Outgoing water temperatures
Heating
°C
20 ~ 60
Cooling
°C
7 ~ 25
DHW
°C
40 ~ 80
Components
Pump
Type
-
High-efficiency pump
Regulation
-
Electronic - continuous control
Capacity (min-max)
W
3 ~ 87
Flow rate (min)
l/h
1150
1150
1150
Flow rate (nom)
l/h
2060
2400
2660
Expansion vessel
Volume*
l
10
Pressure (max)
bar
3
Pre-pressure
bar
1
Electrical heating
Type
-
Wet
Material
-
Incoloy825
Regulation
-
Automatic
Number of steps
-
2
Capacity
kW
6
Combination
kW
3 + 3
Heat exchanger
Type
-
Plate heat exchanger
Number
-
2
Water tank
Volume
L
185
Electrical resistance
kW
3
Sound pressure**
dB (A)
29
Power cable section indoor unit
mm²
5G4
Automatic fuse (slow)
A
20
Dimensions
Unit (LxDxH)
mm
600x650x1800
Weight
kg
195
Specifications and design can change without notice for further improvements
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber