Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.
The integrated water heater (185L) is made of enamelled steel to protect against corrosion on the inside. A anode will protect the tank against ionization.

Brand

  • R-AQUA

Application

  • Heating of new or existing houses
  • Heating by means of radiators, convectors or floor, wall or ceiling heating
  • Cooling by means of convectors, floor, wall or ceiling cooling
  • Heating of domestic water

Composition

  • 3-way valve
  • Communication cable included
  • High efficiency plate heat exchangers
  • Energy-efficient circulation pumps
  • Integrated water heater with thermal stratification (185 liters)

  • Colour touch screen controller (wired)

  • Expansion vessel (10 liters)
  • Safety valve (3 bar)
  • Electrical backup heater
  • Electrical backup heater domestic water
  • electronic anode
  • Water pressure sensor

Refrigerant

  • R32

Specifications

  • Split system
  • 1 device for heating, cooling and domestic hot water
    • Heating assured at outside temperatures down to -25°C
    • Water temperature up to 55°C at outside temperatures down to -10°C
  • A+++ at 35°C water temperature
  • Bivalent setup possible
    • The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.

  • Standard equipped with WiFi
  • Standard equipped with Modbus interface
  • Easy installation
  • EUROVENT EN 14511 and EN 14825 certification
  • Keymark certification

Accessories

  • Room thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
  • Smart Grid module, type SMART GRID
  • Buffer tank, type BTE 60, BTE 100
  • Deaerator, type AAS

  • Magnetic dirt separator, type ADS

  • Differential pressure regulator, type DPC

  • Filling set, type WFS

  • Expansion vessel for heating, type HEV

  • Expansion vessel console, type EVC

  • Protector, type PAB

  • Safety group, type PSG

  • Siphon for pressure safety group, type SSG

  • Expansion vessel for sanitary water, type SEV

  • Connection kit for sanitary expansion vessel, type EVC SAN

  • Pressure regulator, type PRV

  • Coding plug for permanently disabling the cooling function, type COD-ID-H

  • Start-up is strongly recommended, type XSTARTUPJ

Water filter, safety group and expansion vessel MUST be provided on site.

Applicable outdoor units

  • Outdoor unit, type CGW-OU M1

Startup

  • Start-up by CAIROX BELGIUM strongly recommended

Technical data

Indoor unitCGW-ID 12 M1CGW-ID 14 M1CGW-ID 16 M1
Corresponding outdoor unitCGW-OU 12 M1CGW-OU 14 M1CGW-OU 16 M1
Heating capacity A7/W35kW12,0014,0015,50
COP A7/W35 5,004,704,51
Heating capacity A7/W45kW12,2914,4416,13
COP A7/W45 3,983,983,88
Heating capacity A2/W35kW9,6011,2012,32
COP A2/W35 3,423,303,23
Heating capacity A2/W45kW9,3610,9212,01
COP A2/W45 2,742,642,58
Heating capacity A-7/W35kW7,929,2410,16
COP A-7/W35 2,702,602,55
Heating capacity A-7/W45kW7,688,969,86
COP A-7/W45 2,162,082,04
Heating capacity A-10/W35kW7,208,409,24
Heating capacity A-10/W45kW6,968,128,93
SCOP W35/W55 4,48/3,234,45/3,354,45/3,35
Seasonal efficiency ηs heat pump W35/W55%176/126175/131175/131
Annual energy consumption heat pump W35/W55kWh5065/70285552/79586027/7958
Energy class heat pump W35/W55 A+++/A++
Seasonal efficiency ηs DHW W55%112112112
Annual energy consumption DHW W55kWh915915915
Energy class DHW A

Power supply

V / Ph / Hz400/3/50
Refrigerant (GWP) R32 (675)
Refrigerant pipes (liquid - gas)inch1/4 - 5/8
Hydraulic connections (supply - return)inch1
Outgoing water temperaturesHeating°C20 ~ 60
Cooling°C7 ~ 25
DHW°C40 ~ 80
ComponentsPumpType-High-efficiency pump
Regulation-Electronic - continuous control
Capacity (min-max)W3 ~ 87
Flow rate (min)l/h115011501150
Flow rate (nom)l/h206024002660
Expansion vesselVolume*l10
Pressure (max)bar3
Pre-pressurebar1
Electrical heatingType-Wet
Material-Incoloy825
Regulation-Automatic
Number of steps-2
CapacitykW6
CombinationkW3 + 3
Heat exchangerType-Plate heat exchanger
Number-2
Water tankVolumeL185
Electrical resistancekW3
Sound pressure**dB (A)29
Power cable section indoor unitmm²5G4
Automatic fuse (slow)A20
DimensionsUnit (LxDxH)mm600x650x1800
Weightkg195
Specifications and design can change without notice for further improvements
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber
HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...