This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
Air/water inverter controlled heat pump with R32 refrigerant. Thanks to the advanced heat pump technology, the energy from the outside air is absorbed and transferred to the water for heating of the home and the domestic hot water.
The intelligent control of the compressor and expansion valve ensures a precise and fast control of the water temperature, thus reducing the energy consumption.
The integrated water heater (185L) is made of enamelled steel to protect against corrosion on the inside. A anode will protect the tank against ionization.
Brand
R-AQUA
Application
Heating of new or existing houses
Heating by means of radiators, convectors or floor, wall or ceiling heating
Cooling by means of convectors, floor, wall or ceiling cooling
Heating of domestic water
Composition
3-way valve
Communication cable included
High efficiency plate heat exchangers
Energy-efficient circulation pumps
Integrated
water heater with thermal stratification (185 liters)
Colour touch screen controller
(wired)
Expansion vessel (10 liters)
Safety valve (3 bar)
Electrical backup heater
Electrical backup heater domestic water
electronic anode
Water pressure sensor
Refrigerant
R32
Specifications
Split system
1 device for heating, cooling and domestic hot water
Heating assured at outside temperatures down to -25°C
Water temperature up to 55°C at outside temperatures down to -10°C
A+++ at 35°C water temperature
Bivalent setup possible
The heat pump will send a signal to an external heat source (eg gas boiler) depending on the outside temperature. This causes the heat pump stoped, and the second source present will provide the heating.
Standard equipped with WiFi
Standard equipped with Modbus interface
Easy installation
EUROVENT EN 14511 and EN 14825 certification
Keymark certification
Accessories
Room thermostat, type TS-CLOUD, TS-CLOUD RF (only suitable for heating)
Smart Grid module, type SMART GRID
Buffer tank, type BTE 60, BTE 100
Deaerator, type AAS
Magnetic dirt separator, type ADS
Differential pressure regulator, type DPC
Filling set, type WFS
Expansion vessel for heating, type HEV
Expansion vessel console, type EVC
Protector, type PAB
Safety group, type PSG
Siphon for pressure safety group, type SSG
Expansion vessel for sanitary water, type SEV
Connection kit for sanitary expansion vessel, type EVC SAN
Pressure regulator, type PRV
Coding plug
for permanently disabling the cooling function, type COD-ID-H
Start-up is strongly recommended, type XSTARTUPJ
Water filter, safety group and expansion vessel MUST be provided on site.
Applicable outdoor units
Outdoor unit, type CGW-OU M1
Articles
Article selection assistant
Type
Ø [mm]
U [V]
P [W]
Article number
Type
Ø [mm]
U [V]
P [W]
E-shop
J090112100030
CVA-100-1f-300 MPI
100
230/1ph
300
J090112125030
CVA-125-1f-300 MPI
125
230/1ph
300
J090112125060
CVA-125-1f-600 MPI
125
230/1ph
600
J090112125090
CVA-125-1f-900 MPI
125
230/1ph
900
J090112125120
CVA-125-1f-1200 MPI
125
230/1ph
1200
J090112160100
CVA-160-1f-1000 MPI
160
230/1ph
1000
J090112160120
CVA-160-1f-1200 MPI
160
230/1ph
1200
J090112160200
CVA-160-1f-2000 MPI
160
230/1ph
2000
J090112160240
CVA-160-1f-2400 MPI
160
230/1ph
2400
J090112200100
CVA-200-1f-1000 MPI
200
230/1ph
1000
J090112200120
CVA-200-1f-1200 MPI
200
230/1ph
1200
J090112200200
CVA-200-1f-2000 MPI
200
230/1ph
2000
J090112200240
CVA-200-1f-2400 MPI
200
230/1ph
2400
J090112250100
CVA-250-1f-1000 MPI
250
230/1ph
1000
J090112250120
CVA-250-1f-1200 MPI
250
230/1ph
1200
J090112250200
CVA-250-1f-2000 MPI
250
230/1ph
2000
J090112250240
CVA-250-1f-2400 MPI
250
230/1ph
2400
J090112315100
CVA-315-1f-1000 MPI
315
230/1ph
1000
J090112315120
CVA-315-1f-1200 MPI
315
230/1ph
1200
J090112315200
CVA-315-1f-2000 MPI
315
230/1ph
2000
J090112315240
CVA-315-1f-2400 MPI
315
230/1ph
2400
J090212160300
CVA-160-2f-3000 MPI
160
400/2ph
3000
J090212160500
CVA-160-2f-5000 MPI
160
400/2ph
5000
J090212200300
CVA-200-2f-3000 MPI
200
400/2ph
3000
J090212200500
CVA-200-2f-5000 MPI
200
400/2ph
5000
J090212200600
CVA-200-2f-6000 MPI
200
400/2ph
6000
J090212200603
CVA-200-3f-6000 MPI
200
400/3ph
6000
J090212250300
CVA-250-2f-3000 MPI
250
400/2ph
3000
J090212250500
CVA-250-2f-5000 MPI
250
400/2ph
5000
J090212250600
CVA-250-2f-6000 MPI
250
400/2ph
6000
J090212250603
CVA-250-3f-6000 MPI
250
400/3ph
6000
J090212315300
CVA-315-2f-3000 MPI
315
400/2ph
3000
J090212315500
CVA-315-2f-5000 MPI
315
400/2ph
5000
J090212315600
CVA-315-2f-6000 MPI
315
400/2ph
6000
J090212315603
CVA-315-3f-6000 MPI
315
400/3ph
6000
J090212315903
CVA-315-3f-9000 MPI
315
400/3ph
9000
J090212400300
CVA-400-2f-3000 MPI
400
400/2ph
3000
J090212400500
CVA-400-2f-5000 MPI
400
400/2ph
5000
J090212400600
CVA-400-2f-6000 MPI
400
400/2ph
6000
J090212400603
CVA-400-3f-6000 MPI
400
400/3ph
6000
J090212400903
CVA-400-3f-9000 MPI
400
400/3ph
9000
=> Stock product central warehouse, except sales
Startup
Start-up by CAIROX BELGIUM strongly recommended
Technical data
Indoor unit
CGW-ID 12 M1
CGW-ID 14 M1
CGW-ID 16 M1
Corresponding outdoor unit
CGW-OU 12 M1
CGW-OU 14 M1
CGW-OU 16 M1
Heating capacity A7/W35
kW
12,00
14,00
15,50
COP A7/W35
5,00
4,70
4,51
Heating capacity A7/W45
kW
12,29
14,44
16,13
COP A7/W45
3,98
3,98
3,88
Heating capacity A2/W35
kW
9,60
11,20
12,32
COP A2/W35
3,42
3,30
3,23
Heating capacity A2/W45
kW
9,36
10,92
12,01
COP A2/W45
2,74
2,64
2,58
Heating capacity A-7/W35
kW
7,92
9,24
10,16
COP A-7/W35
2,70
2,60
2,55
Heating capacity A-7/W45
kW
7,68
8,96
9,86
COP A-7/W45
2,16
2,08
2,04
Heating capacity A-10/W35
kW
7,20
8,40
9,24
Heating capacity A-10/W45
kW
6,96
8,12
8,93
SCOP W35/W55
4,48/3,23
4,45/3,35
4,45/3,35
Seasonal efficiency ηs heat pump W35/W55
%
176/126
175/131
175/131
Annual energy consumption heat pump W35/W55
kWh
5065/7028
5552/7958
6027/7958
Energy class heat pump W35/W55
A+++/A++
Seasonal efficiency ηs DHW W55
%
112
112
112
Annual energy consumption DHW W55
kWh
915
915
915
Energy class DHW
A
Power
supply
V / Ph / Hz
400/3/50
Refrigerant (GWP)
R32 (675)
Refrigerant pipes (liquid - gas)
inch
1/4 - 5/8
Hydraulic connections (supply - return)
inch
1
Outgoing water temperatures
Heating
°C
20 ~ 60
Cooling
°C
7 ~ 25
DHW
°C
40 ~ 80
Components
Pump
Type
-
High-efficiency pump
Regulation
-
Electronic - continuous control
Capacity (min-max)
W
3 ~ 87
Flow rate (min)
l/h
1150
1150
1150
Flow rate (nom)
l/h
2060
2400
2660
Expansion vessel
Volume*
l
10
Pressure (max)
bar
3
Pre-pressure
bar
1
Electrical heating
Type
-
Wet
Material
-
Incoloy825
Regulation
-
Automatic
Number of steps
-
2
Capacity
kW
6
Combination
kW
3 + 3
Heat exchanger
Type
-
Plate heat exchanger
Number
-
2
Water tank
Volume
L
185
Electrical resistance
kW
3
Sound pressure**
dB (A)
29
Power cable section indoor unit
mm²
5G4
Automatic fuse (slow)
A
20
Dimensions
Unit (LxDxH)
mm
600x650x1800
Weight
kg
195
Specifications and design can change without notice for further improvements
Capacities measured according to EN14511
* The size of the expansion vessel should be determined in accordance with the total water volume of the system
** Measured at 1m distance in a semi-anechoic chamber