This site uses cookies and related technologies, as described in our privacy policy, for purposes that may include site operation, analytics, enhanced user experience, or advertising. You may choose to consent to our use of these technologies, or manage your own preferences.
Heat
recovery unit with condensing wheel, either without battery
or with battery (electrical post heating battery, change-over water battery or
change-over DX battery). The device is available in various versions up to ca. 10.000
m³/h with horizontal connections or ca. 5.000 m³/h with vertical connections and this in left or right version. The device is EPB
tested according to NBN EN 308.
Brand
R-COVERY by SALDA
Application
Ventilation for both residential and non-residential applications
For indoor mounting
Outside mounting only possible for horizontal versions (with optional roof)
Composition
Outer panel: aluzinc RAL7040 (corrosion class C4)
Inner panel: aluzinc (corrosion class C4)
50mm insulation
Mineral wool insulation, fire class A1
Round connections:
for horizontal models up to and including model 2000
for vertical models up to and including model 1500
Rectangular connections:
for horizontal models from model 3000
for vertical models from model 2000
Motorized registers and flexible sleeves available as an OPTION
Possibility of built-in battery (electrical post-heating, change-over water battery or change-over DX battery)
Automatic bypass 0-10V
Modbus communication as a standard
Communication possible via MB-GATEWAY with Modbus/BACnet/TCP-IP (Web server or App)
Constant flow control as a standard
Constant pressure control or CO2 control available as an option (sensors not included)
Filter detection via pressure switch
Controller is not included
Fan
Direct driven direct current EC fan with backward inclined blades
Constant flow regulation
Exchanger
Condensation wheel 0-10V with high efficiency > 80%
Filter
The AmberAir Compact S-R is equipped with bag filters M5 - ISO 16890 ePM10 65% (extraction) / F7 - ISO 16890 ePM1 55% (supply)
Versions
Horizontal versions
AmberAir Compact S-R H xxxxL CO MCB: Horizontal unit with change-over water battery, left-sided version, MCB controller
AmberAir Compact S-R H xxxxR CO MCB: Horizontal unit with change-over water battery, right-sided version, MCB controller
AmberAir Compact S-R H xxxxL DX MCB: Horizontal unit with change-over DX battery, left-sided version, MCB controller
AmberAir Compact S-R H xxxxR DX MCB: Horizontal unit with change-over DX battery, right-sided version, MCB controller
AmberAir Compact S-R H xxxxL BE MCB: Horizontal unit with electric battery, left-sided version, MCB controller
AmberAir Compact S-R H xxxxR BE MCB: Horizontal unit with electric battery, right-sided version, MCB controller
AmberAir Compact S-R H xxxxL NB MCB: Horizontal unit without battery, left-sided version, MCB controller
AmberAir Compact S-R H xxxxR NB MCB: Horizontal unit without battery, right-sided version, MCB controller
Vertical versions:
AmberAir Compact S-R V xxxxL CO MCB: Vertical unit with change-over water battery, left-sided version, MCB controller
AmberAir Compact S-R V xxxxR CO MCB: Vertical unit with change-over water battery, right-sided version, MCB controller
AmberAir Compact S-R V xxxxL DX MCB: Vertical unit with change-over DX battery, left-sided version, MCB controller
AmberAir Compact S-R V xxxxR DX MCB: Vertical unit with change-over DX battery, right-sided version, MCB controller
AmberAir Compact S-R V xxxxL BE MCB: Vertical unit with electric battery, left-sided version, MCB controller
AmberAir Compact S-R V xxxxR BE MCB: Vertical unit with electric battery, right-sided version, MCB controller
AmberAir Compact S-R V xxxxL NB MCB: Vertical unit without battery, left-sided version, MCB controller
AmberAir Compact S-R V xxxxR NB MCB: Vertical unit without battery, right-sided version, MCB controller
Certification
Tested according to NBN EN 308: www.epbd.be
Tested according to EUROVENT classifications according to EN13053
Mechanical strength: D1
Airtightness class: L1
Thermal transfer class: T2
Thermal bridge factor: TB2
Filter leakage: F9
Mounting
Up to model 5000 is delivered in 1 part
All models from size 7000 are delivered in 3 parts
Model 2000 can be dismantled into 2 parts on site
All models from size 3000 can be dismantled into 3 parts on site
Accessories
Touch screen controller, type TS-AIR
Airtight control valve, type AKH / RM-SR(S)
Air outlet, type UT (up to model 2000 H / 1500 V) / OC-SR(S) (from model 3000 H / 2000 V)
Connection piece, type MDV/MTS (up to model 2000 H / 1500 V) / FLEX-SR(S) (from model 3000 H / 2000 V)
Roof for outdoor installation, type RF-SR(S)
Comfort Box (attachment with additional battery) CB
Replacement filter, type FS-SR
Connecting multiple 0-10V sensors MM6-24/D
Order example
AmberAir Compact S-R H 1000L BE MCB
Explanation
S-R = with condenstion wheel
H = horizontal ersion
1000 = size
L = left version
BE = electric post-heating battery
MCB = type of regulation
Articles
Article selection assistant
Type
Cooling capacity [kW]
Heating Capacity* [kW]
Hydraulic connection
Article number
Type
Cooling capacity [kW]
Heating Capacity* [kW]
Hydraulic connection
E-shop
J036151900001
Romeo-ECM-1M-NC/L/2P
0.70
0.87
Left
J036151900002
Romeo-ECM-2M-NC/L/2P
1.49
1.77
Left
J036151900003
Romeo-ECM-3M-NC/L/2P
2.04
2.34
Left
J036151900004
Romeo-ECM-4M-NC/L/2P
2.53
2.78
Left
J036151900005
Romeo-ECM-5M-NC/L/2P
2.84
3.12
Left
J036151900006
Romeo-ECM-6M-NC/L/2P
3.19
3.60
Left
J036151901001
Romeo-ECM-1M-NC/R/2P
0.70
0.87
Right
J036151901002
Romeo-ECM-2M-NC/R/2P
1.49
1.77
Right
J036151901003
Romeo-ECM-3M-NC/R/2P
2.04
2.34
Right
J036151901004
Romeo-ECM-4M-NC/R/2P
2.53
2.78
Right
J036151901005
Romeo-ECM-5M-NC/R/2P
2.84
3.12
Right
J036151901006
Romeo-ECM-6M-NC/R/2P
3.19
3.60
Right
J036151910001
Romeo-ECM-1M-RC/L/2P
0.70
0.87
Left
J036151910002
Romeo-ECM-2M-RC/L/2P
1.49
1.77
Left
J036151910003
Romeo-ECM-3M-RC/L/2P
2.04
2.34
Left
J036151910004
Romeo-ECM-4M-RC/L/2P
2.53
2.78
Left
J036151910005
Romeo-ECM-5M-RC/L/2P
2.84
3.12
Left
J036151910006
Romeo-ECM-6M-RC/L/2P
3.19
3.60
Left
J036151911001
Romeo-ECM-1M-RC/R/2P
0.70
0.87
Right
J036151911002
Romeo-ECM-2M-RC/R/2P
1.49
1.77
Right
J036151911003
Romeo-ECM-3M-RC/R/2P
2.04
2.34
Right
J036151911004
Romeo-ECM-4M-RC/R/2P
2.53
2.78
Right
J036151911005
Romeo-ECM-5M-RC/R/2P
2.84
3.12
Right
J036151911006
Romeo-ECM-6M-RC/R/2P
3.19
3.60
Right
J036151920001
Romeo-ECM-1M-RC/TD/L/2P
0.70
0.87
Left
J036151920002
Romeo-ECM-2M-RC/TD/L/2P
1.49
1.77
Left
J036151920003
Romeo-ECM-3M-RC/TD/L/2P
2.04
2.34
Left
J036151920004
Romeo-ECM-4M-RC/TD/L/2P
2.53
2.78
Left
J036151920005
Romeo-ECM-5M-RC/TD/L/2P
2.84
3.12
Left
J036151920006
Romeo-ECM-6M-RC/TD/L/2P
3.19
3.60
Left
J036151921001
Romeo-ECM-1M-RC/TD/R/2P
0.70
0.87
Right
J036151921002
Romeo-ECM-2M-RC/TD/R/2P
1.49
1.77
Right
J036151921003
Romeo-ECM-3M-RC/TD/R/2P
2.04
2.34
Right
J036151921004
Romeo-ECM-4M-RC/TD/R/2P
2.53
2.78
Right
J036151921005
Romeo-ECM-5M-RC/TD/R/2P
2.84
3.12
Right
J036151921006
Romeo-ECM-6M-RC/TD/R/2P
3.19
3.60
Right
J036151930001
Romeo-ECM-1M-RC/TD/App/L/2P
0.70
0.87
Left
J036151930002
Romeo-ECM-2M-RC/TD/App/L/2P
1.49
1.77
Left
J036151930003
Romeo-ECM-3M-RC/TD/App/L/2P
2.04
2.34
Left
J036151930004
Romeo-ECM-4M-RC/TD/App/L/2P
2.53
2.78
Left
J036151930005
Romeo-ECM-5M-RC/TD/App/L/2P
2.84
3.12
Left
J036151930006
Romeo-ECM-6M-RC/TD/App/L/2P
3.19
3.60
Left
J036151931001
Romeo-ECM-1M-RC/TD/App/R/2P
0.70
0.87
Right
J036151931002
Romeo-ECM-2M-RC/TD/App/R/2P
1.49
1.77
Right
J036151931003
Romeo-ECM-3M-RC/TD/App/R/2P
2.04
2.34
Right
J036151931004
Romeo-ECM-4M-RC/TD/App/R/2P
2.53
2.78
Right
J036151931005
Romeo-ECM-5M-RC/TD/App/R/2P
2.84
3.12
Right
J036151931006
Romeo-ECM-6M-RC/TD/App/R/2P
3.19
3.60
Right
Prices right version = prices left version
Selection curves
Selection curves
Selection curves
Selection curves
Selection curves
Graphs only valid for device types NB, other selections on request